Thrombus extraction catheter iVascular capturer

Thrombus extraction catheter iVascular capturer

The iVascular capturer thrombus extraction catheter is a quick-change catheter with a single proximal lumen and dual distal lumens.

The catheter is compatible with a 0.014 inch = 0.36 mm guidewire.

The larger lumen extends from proximal to distal and is designed to remove the thrombus by connecting to one of the syringes included in the kit. The smaller lumen occupies only the last 17.5 cm of the distal segment of the catheter and is designed to accommodate a guidewire, facilitating the advancement of the catheter to the working area.

There is a radiopaque mark inside the catheter tip, which allows you to determine the position of the catheter in the artery cavity at any time. At a distance of 15 mm from it there is a second radiopaque mark, which allows you to determine the size of the lesion.

The usable length of the catheter is 140 cm. Available in two variations:

DETR14145601 – 6F Thrombus Aspiration Catheter: can be inserted inside a 6F guiding catheter with a minimum internal diameter of 1.78 mm.

DETR14145701 – 7F Thrombus Aspiration Catheter: can be inserted inside a 7F guiding catheter with a minimum internal diameter of 2.00 mm.

Indications

The Capturer Thrombus Aspiration Catheter is specifically intended for the removal of recently formed soft emboli and thrombi in the coronary or peripheral vascular system, with a minimum diameter of 2 mm.

Дополнительные сведения

Производитель

Страна Производитель

Испания

Request a commercial offer
Описание

The iVascular capturer thrombus extraction catheter is a quick-change catheter with a single proximal lumen and dual distal lumens.

The catheter is compatible with a 0.014 inch = 0.36 mm guidewire.

The larger lumen extends from proximal to distal and is designed to remove the thrombus by connecting to one of the syringes included in the kit. The smaller lumen occupies only the last 17.5 cm of the distal segment of the catheter and is designed to accommodate a guidewire, facilitating the advancement of the catheter to the working area.

There is a radiopaque mark inside the catheter tip, which allows you to determine the position of the catheter in the artery cavity at any time. At a distance of 15 mm from it there is a second radiopaque mark, which allows you to determine the size of the lesion.

The usable length of the catheter is 140 cm. Available in two variations:

DETR14145601 – 6F Thrombus Aspiration Catheter: can be inserted inside a 6F guiding catheter with a minimum internal diameter of 1.78 mm.

DETR14145701 – 7F Thrombus Aspiration Catheter: can be inserted inside a 7F guiding catheter with a minimum internal diameter of 2.00 mm.

Indications

The Capturer Thrombus Aspiration Catheter is specifically intended for the removal of recently formed soft emboli and thrombi in the coronary or peripheral vascular system, with a minimum diameter of 2 mm.

Description
Technical specifications
Video

The iVascular capturer thrombus extraction catheter is a quick-change catheter with a single proximal lumen and dual distal lumens.

The catheter is compatible with a 0.014 inch = 0.36 mm guidewire.

The larger lumen extends from proximal to distal and is designed to remove the thrombus by connecting to one of the syringes included in the kit. The smaller lumen occupies only the last 17.5 cm of the distal segment of the catheter and is designed to accommodate a guidewire, facilitating the advancement of the catheter to the working area.

There is a radiopaque mark inside the catheter tip, which allows you to determine the position of the catheter in the artery cavity at any time. At a distance of 15 mm from it there is a second radiopaque mark, which allows you to determine the size of the lesion.

The usable length of the catheter is 140 cm. Available in two variations:

DETR14145601 – 6F Thrombus Aspiration Catheter: can be inserted inside a 6F guiding catheter with a minimum internal diameter of 1.78 mm.

DETR14145701 – 7F Thrombus Aspiration Catheter: can be inserted inside a 7F guiding catheter with a minimum internal diameter of 2.00 mm.

Indications

The Capturer Thrombus Aspiration Catheter is specifically intended for the removal of recently formed soft emboli and thrombi in the coronary or peripheral vascular system, with a minimum diameter of 2 mm.

No technical specifications available.

Request a commercial offer